License Key Not Available Wincc Logging For Runtime Advanced

"License key not available! WinCC Logging for Runtime Advanced" occurs because WinCC Runtime Advanced follows a different licensing model than Comfort Panels. While basic logging is often included in hardware panels, it is a separate paid option for PC-based Runtime Advanced systems. Why the Error Appears Missing Option License: You likely have a valid license (e.g., 128, 512, or 2048 tags) for the Runtime itself, but you do not have the "WinCC Logging for Runtime Advanced" option license. Configured Logging: The message is triggered as soon as you configure a under "Historical data" in your TIA Portal project tree. Audit Trail: Enabling Good Manufacturing Practice (GMP) or Audit features also automatically requires the Logging license. How to Fix It 1. Add the Required License To use logging in a productive environment, you must purchase and transfer the specific license key: Product Name: SIMATIC WinCC Logging for Runtime Advanced MLFB (Order Code): 6AV2107-0GA00-0BB0 Installation: Automation License Manager (ALM) to transfer the key to the Runtime PC. 2. Disable Logging (Workaround) If you don't actually need historical data and want the message to stop, remove the features triggering it: Delete Logs: Historical data > Data logs Historical data > Alarm logs in the project tree and delete all entries. Disable GMP: Navigate to Runtime Settings > Good Manufacturing Practice and uncheck the "Good Manufacturing Practice" box. Recompile: Perform a "Software (rebuild all)" on the HMI and download the project again. 3. Check for "Defective" Licenses If you already own the license but the error persists, check the ALM. Licenses can be marked as "defective" if the IPC was not shut down properly. If marked red/defective, you may need to contact Siemens Technical Support to restore them. If you are only seeing this during Simulation in TIA Portal, you can ignore it; the simulation will still function correctly even without the license. current order codes for the latest WinCC Runtime Advanced versions?

The "License key not available! WinCC Logging for Runtime Advanced" error is a common hurdle in Siemens TIA Portal projects when transitioning from engineering to live operation. This error occurs because WinCC Runtime Advanced requires a dedicated, additional license for data and alarm logging. Core Cause: The "Option" Requirement The primary reason for this error is that WinCC Logging is considered an "option" rather than a built-in feature of the standard Runtime license. Standard License: Covers basic Runtime operations like screen navigation and PLC communication (PowerTags). Logging License: Specifically enables the archiving of historical process data (Tag Logs) and Alarm Logs. Comfort Panels vs. PC Runtime: While physical Comfort Panels include logging capabilities without extra cost, the PC-based WinCC Runtime Advanced requires you to purchase the logging option separately. Troubleshooting and Solutions 1. Verify and Install the Missing License If you are logging process tags or alarms, you must have the SIMATIC WinCC Logging for Runtime Advanced license (e.g., Article No: 6AV2107-0GA00-0BB0 ). Action: Check your Siemens Automation License Manager (ALM) to see if this license is present on your local drive or USB. Recovery: If the license was previously installed but is now missing or marked "defective" (red cross), it may be due to an improper IPC shutdown. Use the Official Siemens Support Request to recover damaged licenses if you have the original Certificate of License. 2. Disable Logging (Workaround for No-Cost) If you do not actually need to save historical data and only want to clear the error message, you can disable the logging functions in your project.

Troubleshooting "License Key Not Available" for WinCC Logging (Runtime Advanced) Few things are more frustrating than spending hours configuring your HMI project, only to be greeted by a cryptic red error message when you hit "Start Runtime." If you are seeing the error "License key not available for WinCC Logging for Runtime Advanced," you are not alone. This specific error halts data logging, stops archiving, and prevents you from viewing historical trends. In this post, we’ll break down exactly why this happens and, more importantly, how to fix it. What Does This Error Actually Mean? WinCC (TIA Portal) uses a granular licensing system. "Runtime Advanced" is the engine that runs your HMI project on a PC station (as opposed to a dedicated Panel). "WinCC Logging" is the add-on feature responsible for collecting, archiving, and displaying process values over time. The error message means your license file is missing, corrupted, or insufficient for the amount of tags you are trying to log. Common Causes Before diving into fixes, identify which scenario fits your situation:

No License Installed: You are running a trial version that has expired, or you never installed the 6AV2105-0xxx series license. Wrong License Type: You own a WinCC Runtime Advanced license (for visualization) but forgot to purchase the "WinCC Runtime Advanced Logging" add-on license. These are sold separately. Power Pack Limit Exceeded: Your license allows a certain number of "Power Tags" (logged variables). If you configured 200 tags but only have a 128-tag license, this error appears. Floating License Issue: You are using a dongle (USB license) that is not properly detected or is being used on another computer on the network. license key not available wincc logging for runtime advanced

Step-by-Step Fixes Follow these steps in order to resolve the issue. 1. Check the "License Sizes" in Your Project (The Most Common Fix) Many users forget they have to assign the logging license to a specific tag quantity.

Open TIA Portal. Go to Runtime Settings > License . Look for the row labeled "WinCC Runtime Advanced Logging." Click the drop-down menu. Does it say "Unlicensed" ? Action: Select the correct license size (e.g., 128, 512, 2048, 10000, or Unlimited) that matches the USB dongle inserted in your PC.

2. Verify the Automation License Manager (ALM) Windows sometimes disables background services. "License key not available

Press Windows + R , type services.msc , and hit Enter. Scroll down to "Automation License Manager Service." Ensure the Status is "Running" and Startup Type is "Automatic." If it is stopped, right-click it and select Start .

3. Run the "License Cleanup" Tool Damaged license cache files are a known issue in older TIA versions.

Close TIA Portal completely. Navigate to C:\Program Files (x86)\Common Files\Siemens\ALM\ . Run ALMCleanUp.exe (Administrator rights required). Restart your PC and re-insert your license dongle. Why the Error Appears Missing Option License: You

4. Update the License Key Firmware (Dongle Users) If you are using a USB dongle (like the green C79040-Gxxxx key), outdated firmware can cause detection failures.

Download the "Automation License Manager Updater" from the Siemens support site. Run the tool, select your USB dongle, and click "Update Firmware."